Laser Scan Micrometer LSM – 9506 Series 544

$8,046.00

Bench Top Type Non-contact Measuring System

Clear
Qty:
SKU: N/A Category:

Description

SKUModelRangeResolutionRepeatabilityAccuracyPositional Error (optical axis/scanning direction)Measuring AreaScanning rateLaser wavelengthLaser scanning speedDisplay unitStandard interfaceOptional interfaceData outputPower supplyOperating environmentPriceBuyhf:att:pa_colorhf:att:pa_item-type
544-116-1ALSM-9506.02-2.36in 0.5-60mm.000002-.005in 0.00005-0.1mm.00003in-0.6umLinearity (*2) – ± .0001in (±2.5µm) – The optical axis direction ± .0001in (±2.5µm) – The scanning direction ±(.00008+L/10000)in [L:inch] (*3) – ±(2.0+L/10)µm [L:mm] (*3)±2.5µm (±.0001") L: Displacement between work piece center and optical axis center.02-2.36in 5-60mm1600per sec650nm (Visible)*5226m/s (8900" / s)16-digit dot matrix (upper column) + 7 segment 11-digit (lower column),guidance LEDsRS-232C, Digimatic code output unit (1ch)NoRS-232C,VO Analog Interface, SPCAC100V to 240V, 50/60Hz, 40VA0 to 40°C, RH 35 to 85% (no condensation)$8,046.00
Qty:

Optional Accessories

SKUDescriptionPriceBuy
936937SPC CABLE (STANDARD TYPE), 1M$43.07
Qty:
264-016-10INPUT TOOL, USB, FOR DIGIMATIC GAUGE$177.30
Qty:
937179TFOOT SWITCH$78.21
Qty:
02AGD170CALIBRATION GAUGE SET FOR LSM-9506$678.60
Qty:
02AGD680ADJUSTABLE STAGE (300) FOR LSM-9506$3,114.00
Qty:
02AGD580CENTER SUPPORT$790.20
Qty:
02AGD590ADJUSTABLE V BLOCK FOR LSM506$954.00
Qty:

Features

Bench Top Type Non-contact Measuring System

Optional Accessories

02AGD170 Calibration gage set (ø1.0mm, ø60mm)
02AGD680 Adjustable Workstage
02AGD580 Center support*
02AGD590 Adjustable V-block*
936937 SPC output cable (1m)
937179T Footswitch
264-012-10 USB Input Tool for spreadsheets (SPC cable also required)

*Use with an adjustable workstage.

Additional information

Weight N/A
Dimensions N/A
Model

LSM-9506

Range

.02-2.36in 0.5-60mm

Resolution

.000002-.005in 0.00005-0.1mm

Repeatability

.00003in-0.6um

Accuracy

Linearity (*2) – ± .0001in (±2.5µm) – The optical axis direction ± .0001in (±2.5µm) – The scanning direction ±(.00008+L/10000)in [L:inch] (*3) – ±(2.0+L/10)µm [L:mm] (*3)

Positional Error

±2.5µm (±.0001") L: Displacement between work piece center and optical axis center

Measuring Area

.02-2.36in 5-60mm

Scanning Rate

1600per sec

Laser Wavelength

650nm (Visible)*5

Laser Scanning Speed

226m/s (8900" / s)

Display Unit

16-digit dot matrix (upper column) + 7 segment 11-digit (lower column),guidance LEDs

Standard Interface

RS-232C, Digimatic code output unit (1ch)

Optional Interface

No

Data Output

RS-232C,VO Analog Interface, SPC

Power Supply

AC100V to 240V, 50/60Hz, 40VA

Operating Environment

0 to 40°C, RH 35 to 85% (no condensation)